Memcom
No connection to Hub with Memcom
Fault Finding - No Connection from the Avire Hub to a Memcom There are a couple of troubleshooting methods you should take when you have no connection t...
Thu, 10 Oct, 2019 at 10:13 AM
➢ Memcom Technical Alarms There are two categories that require intervention: 1]. Missing Background Calls (EN81-28) 2]. Technical Alarms ➢ Missing B...
Thu, 10 Oct, 2019 at 10:27 AM
There could be a few reasons for this situation but the most common cause is that the telephone line is not active. Connect the telephone handset and make a...
Thu, 7 Apr, 2022 at 11:07 AM
This can be caused by the alarm button being a Normally Closed contact, this can be changed in the settings (Settings> System Config, select N/C) (defaul...
Thu, 7 Apr, 2022 at 11:08 AM
Alarm push button is wired through door alarm filtering and to activate would require lift doors to be closed or lift in a fault condition Alarm button no...
Thu, 7 Apr, 2022 at 11:09 AM
A shorting wire can be placed directly across Memcom empty terminals 9 & 15 (Alarm button contacts) , after 4/5 seconds Memcom will dial out if this doe...
Thu, 7 Apr, 2022 at 11:09 AM
Tech alarm and Background numbers should be programmed to the Avire HUB number 03308084733 The correct protocol should be used **3 (P100 is recommended) ...
Thu, 7 Apr, 2022 at 11:11 AM
Press and hold the # key, display will show unit resetting and call will end.
Thu, 7 Apr, 2022 at 11:12 AM
There are a couple of options: Remove alarm wires from your Alarm button and wire these to 5 & 6 contacts on the Memcom terminal, th...
Thu, 7 Apr, 2022 at 11:13 AM
The relay will be closed until line fault occurs and then the relay will switch to open for failsafe operation.
Thu, 7 Apr, 2022 at 11:16 AM