Panachrome
This flashing indicates that a TX or RX diode has failed on one of the detectors. With the exception of the failed diode, the detectors continue to operate ...
Wed, 26 Jan, 2022 at 2:50 PM
Yes, the Panachrome 2D Controller settings can be changed but 3D Panachrome detectors will only work in 2D mode. On the Panachrome 2D Controller, change SW...
Wed, 26 Jan, 2022 at 2:51 PM
Yes, the Panachrome 3D Controller settings can be changed but 2D Panachrome detectors will only work in 2D mode. On the Panachrome 3D Controller, change SW...
Wed, 26 Jan, 2022 at 2:51 PM
This is due to the Test Switch (SW3) still being in the ON position. Switch this to OFF and normal operation will resume
Wed, 26 Jan, 2022 at 2:52 PM
This fault is indicating that the TX & RX cables have been reversed. Check TX & RX cables are installed correctly.
Wed, 26 Jan, 2022 at 2:52 PM